| Note I = inspect and clean, adjust, replace or lubricate as necessary. R = replace. T = tighten. |

Lubrication pointsTo sensor removal and installation
Removal
Remove the ap sensor. Refer to “ap sensor removal and installation” .
Disconnect the coupler (1) and remove the to
sensor (2).
Installation
Install the to sensor in the reverse order of removal.
Pay attention to the following point:
when installing the to s ...
Cooling fan inspection
Cooling fan operating temperature
standard
(on → off): approx. 100 ?‹C (212 ƒ‹f)
(off → on): approx. 105 ?‹C (221 ƒ‹f)
Inspect the cooling fan in the following procedures:
disconnect the cooling fan motor coupler (1).
Test the cooling fan motor for load ...
DTC “c14” (p0120-h/l): tp sensor circuit
malfunction
Detected condition and possible cause
Detected condition
Possible cause
C14
Output voltage is not within the following
range.
Difference between actual throttle opening
and opening calculated by ecm is larger
than specified value.
0.2 V ≤ Sensor ...