Fuel level gauge inspection
Inspect the fuel level gauge in the following procedures:
remove the fuel pump. Refer to “fuel pump disassembly and assembly” in
section 1g .
Measure the resistance at each fuel level gauge in
float position. If the resistance is incorrect, replace
fuel level gauge with a ne ...
Voltage check
If voltage is supplied to the circuit being checked, voltage
check can be used as circuit check.
With all connectors/couplers connected and voltage
applied to the circuit being checked, measure
voltage between each terminal and body ground.
If measurements were taken as shown ...
Air cleaner element removal and installation
Removal
Lift and support the fuel tank. Refer to “fuel tank
removal and installation” in section 1g (page 1g-
9).
Remove the air cleaner box cover (1).
Remove the air cleaner element (2).
Installation
Installation is in the reverse order of removal. ...